1. Liquid Fuel Retail Outlet
— ✓ X n.a. 1 Fixed/permanent dispensing pump 6m. min. from potential source of ignition
— ✓ X n.a. 2 No open flame within 15m. minimum
— ✓ X n.a. 3 5.5m. maximum length of dispensing hose
— ✓ X n.a. 4 Volume-Peso amount display up to two decimal places
— ✓ X n.a. 5 Pump Island with min. 3.5m. x 1.2m. dimension
— ✓ X n.a. 6 Lane-oriented pump with min. 0.05m. distance from fixed object
— ✓ X n.a. 7 Pump guard/column post as safety barrier
— ✓ X n.a. 8 7m. minimum width each ingress & egress
— ✓ X n.a. 9 6m. minimum edge to edge distance between pump islands
— ✓ X n.a. 10 6m. minimum side to side distance between pump islands
— ✓ X n.a. 11 Office/Cashier's booth
— ✓ X n.a. 12 4.5m minimum canopy height
— ✓ X n.a. 13 Boundary walls (concrete or cyclone fence)
— ✓ X n.a. 14 Master switch in case of emergency
— ✓ X n.a. 15 Clean restroom with water supply
— ✓ X n.a. 16 UGT has 1m. min. distance from property line and adjoining structure
— ✓ X n.a. 17 UGT with monitoring wells and fill sump (rain tight)
— ✓ X n.a. 18 3.65m. minimum height of vent lines
2. Marine Retail Outlet
— ✓ X n.a. 1 Tank is petroleum compatible with corrosion-resistant bund walls
— ✓ X n.a. 2 Tank is appropriately protected with no visible mark of corrosion
— ✓ X n.a. 3 Volume-Peso amount display up to two decimal places
— ✓ X n.a. 4 Automatic shut-off nozzle
— ✓ X n.a. 5 Wharf operation or near costal/shoreline
— ✓ X n.a. 6 Fixed/permanent dispensing pump 6m. min. from potential source of ignition
— ✓ X n.a. 7 No open flame within 15m.
— ✓ X n.a. 8 Piping between dispensing and tank areas are protected against impact
— ✓ X n.a. 9 Serving exclusively for marine vessels
3. Technology-Solution Retail Outlet
— ✓ X n.a. 1 1 kilometer minimum distance from existing Retail Outlet
— ✓ X n.a. 2 No other commercial establishment shall be installed/constructed within the Retail Outlet other than those necessary for its operation
— ✓ X n.a. 3 The vehicle being serviced and the delivery of the LF by the Tank Truck shall at all times be inside the business premises
— ✓ X n.a. 4 1m. min. setback distance between dispensing pump and firewall
— ✓ X n.a. 5 1m. min. working distance between tank truck and firewall
— ✓ X n.a. 6 2000 liter maximum capacity per product
— ✓ X n.a. 7 Tank is petroleum compatible except plastic type material
— ✓ X n.a. 8 Tank is appropriately protected with no visible mark of corrosion
— ✓ X n.a. 9 Volume-Peso amount display up to two decimal places
— ✓ X n.a. 10 5.5m. maximum length of dispensing hose
— ✓ X n.a. 11 Automatic shut-off nozzle
— ✓ X n.a. 12 Fixed & permanent dispensing pump 6m. min. from potential source of ignition
— ✓ X n.a. 13 No open flame within 15m.
— ✓ X n.a. 14 Piping between dispensing and tank areas are protected against impact